Advantages of Bac Cooling Tower:
1. Bac Cooling Tower Super Cooling Performance:
Our bac cooling tower adopts a unique combination of single-layer copper tubes and fillers. The bac cooling tower's coils are in close contact with the fillers, the wind speed of cooling tower systems are consistent, the water spray is slow and uniform, the evaporation is sufficient. The temperature difference of each component of the bac cooling tower is uniform. And the cooling efficiency of bac cooling tower is greatly improved.
2. Baltimore Aircoil Cooling Tower Reliable And Convenient Coil Connection:
The coil of bac cooling tower adopts a special design to place the cooling water inlet and outlet headers inside the tower body, and there is no header outside the tower body, cooling tower systems are convenient for disassembly and replacement. The coil of cooling towers and chillers is connected by flange. Cooling tower systems are reliable and safe, and easy to disassemble; the flange connected to the coil is made of fiberglass, which has high strength, protects the coil, and avoids electrochemical corrosion.
3. Bac Cooling Tower Unique :
The bac cooling tower's coil adopts high-efficiency and corrosion-resistant phosphating deoxidized seamless copper tubes, lean processing, and convenient fluid discharge; the built-in spray pipe saves external space. Bac cooling tower makes the tower beautiful. And bac cooling tower is easy to inspect and maintain.
Baltimore Aircoil Cooling Tower:

Working Principle of Cooling Towers And Chillers:
Cooling towers and chillers are a device that allows the working fluid (water or other liquid) to flow in a closed pipe isolated from the air. And cooling towers and chillers exchange heat with the outside air through the pipe wall. Cooling towers ultimately cooling. Cooling tower systems' spray water circulation, commonly known as external circulation. Cooling tower systems have the same principle as an open cooling tower: the spray water is sucked from the water collection tank by the spray pump, flows into the distribution basin, and flows into the heat exchange filler after being evenly distributed through the perforated plate. Due to the action of the fan, the evaporation of the water is accelerated and the heat is taken away. The spray water is cooled in the cooling coil and the heat of cooling tower systemsis transferred to the working fluid to complete the cooling. Finally, the spray water flows into the water collection tank and then flows to the distribution basin. This continuous cycle of cooling towers and chillers allow the working fluid to be continuously cooled.

Specification of Cooling Towers And Chillers:
Model | WATER FLOW | DIMENSIONS(mm) | FAN ASSEMBLY | SPRAY WATER | PIPE DIMENSIONS x NUMBER | COIL PIPE | DEAD WEIGHT | RUNNING WEIGHT | |||||
m3/h | W | L | H | DIMENSION x MOTOR SET Mm x SET kW x SET | PUMP kW x SET | HOT WATER COLD WATER INLET PIPE OUTIHPIPE | MAKEUP WATER PIPE | OVERFLOW PIPE | DRAIN PIPE | PRESS DROP kPa | kg | kg | |
CCT-D30CUF | 30 | 2050 | 2400 | 2472 | 1300x1 1.5x1 | 0.75 x 1 | 65x1 65x1 | 25x1 | 40x1 | 40x1 | 102 | 790 | 1,420 |
CCT-D40CUF | 40 | 2050 | 2400 | 2892 | 1300x1 2.2x1 | 0.75x1 | 80x1 80x1 | 25x1 | 40x1 | 40x1 | 97 | 910 | 1,630 |
CCT-D50CUF | 50 | 2050 | 2400 | 3312 | 1300x1 4.0x1 | 0.75x1 | 80x1 80x1 | 25x1 | 40x1 | 40x1 | 93 | 1,000 | 1,790 |
CCT-D60CUF | 60 | 2050 | 3550 | 2472 | 1500x1 4.0x1 | 1.5x1 | 100x1 100x1 | 25x1 | 40x1 | 40x1 | 102 | 1,220 | 2,280 |
CCT-D70CUF | 70 | 2050 | 3550 | 2682 | 1600x1 5.5x1 | 1.5x1 | 100x1 100x1 | 25x1 | 40x1 | 40x1 | 99 | 1,340 | 2,480 |
CCT-D80CUF | 80 | 2050 | 3550 | 2892 | 1700x1 5.5x1 | 1.5x1 | 125x1 125x1 | 25x1 | 40x1 | 40x1 | 97 | 1,450 | 2,690 |
CCT-D90CUF | 90 | 2050 | 3550 | 3172 | 1700x1 5.5x1 | 1.5x1 | 125x1 125x1 | 25x1 | 40x1 | 40x1 | 88 | 1,550 | 2,910 |
CCT-D100CUF | 100 | 2050 | 3550 | 3312 | 1700x1 7.5x1 | 1.5x1 | 125x1 125x1 | 25x1 | 40x1 | 40x1 | 93 | 1600 | 3,010 |
CCT-D110CUF | 110 | 2400 | 3850 | 3452 | 1850x1 7.5x1 | 1.5x1 | 125x1 125x1 | 25x1 | 40x1 | 40x1 | 100 | 1,880 | 3,560 |
CCT-D125CUF | 125 | 2400 | 3850 | 3732 | 2000x1 7.5x1 | 1.5x1 | 125x1 125x1 | 25x1 | 40x1 | 40x1 | 101 | 2,040 | 3,850 |
CCT-D135CUF | 135 | 2400 | 3850 | 4232 | 2000x1 11 x1 | 1.5x1 | 125x1 125x1 | 25x1 | 40x1 | 40x1 | 99 | 2,140 | 4,040 |
CCT-D150CUF | 150 | 2400 | 3850 | 4432 | 2200x1 11 x1 | 1.5x1 | 150x1 150x1 | 25x1 | 40x1 | 40x1 | 100 | 2,310 | 4,340 |
CCT-D160CUF | 160 | 2400 | 3850 | 4642 | 2200x1 11 x1 | 1.5x1 | 150x1 150x1 | 25x1 | 40x1 | 40x1 | 99 | 2,410 | 4,540 |
CCT-D180CUF | 180 | 4100 | 3550 | 3172 | 1700x2 5.5x2 | 1.5x2 | 125x2 125x2 | 25x2 | 40x2 | 40x2 | 88 | 3,020 | 5,730 |
CCT-D200CUF | 200 | 4100 | 3550 | 3312 | 1700x2 7.5x2 | 1.5x2 | 125x2 125x2 | 25x2 | 40x2 | 40x2 | 93 | 3,110 | 5,930 |
CCT-D220CUF | 220 | 4800 | 3850 | 3452 | 1850x2 7.5x2 | 1.5x2 | 125x2 125x2 | 25x2 | 40x2 | 40x2 | 100 | 3,610 | 6,980 |
CCT-D250CUF | 250 | 4800 | 3850 | 3732 | 2000x2 7.5x2 | 1.5x2 | 125x2 125x2 | 25x2 | 40x2 | 40x2 | 101 | 3,960 | 7,580 |
CCT-D270CUF | 270 | 4800 | 3850 | 4232 | 2000x2 11 x2 | 1.5x2 | 125x2 125x2 | 25x2 | 40x2 | 40x2 | 99 | 4,150 | 7,960 |
CCT-D300CUF | 300 | 4800 | 3850 | 4432 | 2200x2 11 x2 | 1.5x2 | 150x2 150x2 | 25x2 | 40x2 | 40x2 | 100 | 4,480 | 8,550 |
CCT-D320CUF | 320 | 4800 | 3850 | 4642 | 2200x2 11 x2 | 1.5x2 | 150x2 150x2 | 25x2 | 40x2 | 40x2 | 99 | 4,680 | 8,940 |
CCT-D375CUF | 375 | 7200 | 3850 | 3732 | 2000x3 7.5x3 | 1.5x3 | 125x3 125x3 | 25x3 | 40x3 | 40x3 | 101 | 5,890 | 11,320 |
CCT-D405CUF | 405 | 7200 | 3850 | 4232 | 2000x3 11 x3 | 1.5x3 | 125x3 125x3 | 25x3 | 40x3 | 40x3 | 99 | 6,170 | 11,880 |
CCT-D450CUF | 450 | 7200 | 3850 | 4432 | 2200x3 11 x3 | 1.5x3 | 150x3 150x3 | 25x3 | 40x3 | 40x3 | 100 | 6,660 | 12,760 |
CCT-D480CUF | 480 | 7200 | 3850 | 4642 | 2200x3 11 x3 | 1.5x3 | 150x3 150x3 | 25x3 | 40x3 | 40x3 | 99 | 6,950 | 13,340 |
CCT-D500CUF | 500 | 9600 | 3850 | 3732 | 2000x4 7.5x4 | 1.5x4 | 125x4 125x4 | 25x4 | 40x4 | 40x4 | 101 | 7,810 | 15,060 |
CCT-D540CUF | 540 | 9600 | 3850 | 4232 | 2000x4 11 x4 | 1.5x4 | 125x4 125x4 | 25x4 | 40x4 | 40x4 | 99 | 8,190 | 15,800 |
CCT-D600CUF | 600 | 9600 | 3850 | 4432 | 2200x4 11 x4 | 1.5x4 | 150x4 150x4 | 25x4 | 40x4 | 40x4 | 100 | 8,840 | 16,970 |
CCT-D640CUF | 640 | 9600 | 3850 | 4642 | 2200x4 11 x4 | 1.5x4 | 150x4 150x4 | 25x4 | 40x4 | 40x4 | 99 | 9,220 | 17,740 |
CCT-D675CUF | 675 | 12000 | 3850 | 4232 | 2000x5 11 x5 | 1.5x5 | 125x5 125x5 | 25x5 | 40x5 | 40x5 | 99 | 10,200 | 19,720 |
CCT-D750CUF | 750 | 12000 | 3850 | 4432 | 2200x5 11 x5 | 1.5x5 | 150x5 150x5 | 25x5 | 40x5 | 40x5 | 100 | 11,010 | 21,180 |
CCT-D800CUF | 800 | 12000 | 3850 | 4642 | 2200x5 11 x5 | 1.5x5 | 150x5 150x5 | 25x5 | 40x5 | 40x5 | 99 | 11,490 | 22,140 |
CCT-D900CUF | 900 | 14400 | 3850 | 4432 | 2200x6 11 x6 | 1.5x6 | 150x6 150x6 | 25x6 | 40x6 | 40x6 | 100 | 13,190 | 25,390 |
CCT-D960CUF | 960 | 14400 | 3850 | 4642 | 2200x6 11 x6 | 1.5x6 | 150x6 150x6 | 25x6 | 40x6 | 40x6 | 99 | 13,830 | 26,600 |
冷却塔和冷水机组的环境保护:
巴尔的摩空冷塔节约水资源。与开放式冷却塔相比,空冷塔通过循环水来减少过度用水。此外,巴尔的摩空冷塔的设计特点减少了蒸发水的损失。巴尔的摩空冷塔可以提高水的利用率,并降低运行成本。与开放式冷却塔不同,巴尔的摩空冷塔不会直接排放水蒸气。巴尔的摩空冷塔适用于对环境要求严格的行业。
冷却塔和冷水机组的维护:
冷却塔系统采用特殊设计,可减少清洁和维护频率,降低人工成本,且易于拆卸,有效减少停机时间。巴尔的摩空冷式冷却塔可降低维护成本。

公司简介: